| Multi-circuit
DEFROST
CONTROLS PRECISION
5000 Series |
|
|
|
|
MODEL |
VAC |
HZ |
#
of
Switches |
#
of
MOTORS |
Unit
Price |
Add
to cart |
5010-0B |
120 |
60 |
8 |
1 |
$372.00 |
|
5010-3B |
240 |
60 |
8 |
1 |
$380.00 |
|
5011 |
N/A |
N/A |
8 |
None
(slave) |
$335.00 |
|
5014 |
N/A |
N/A |
4 |
None
(slave) |
$215.00 |
|
5015-0B |
120 |
60 |
4 |
1 |
$232.00 |
|
5015-3B |
240 |
60 |
4 |
1 |
$241.00 |
|
All
pricing in US dollars. |
Models 5010, 5011, 5014, 5015
- Model
5010 and 5011 have eight SPDT switches. “R”- normally
closed, “D” - normally open.Eight normally open auxiliary
contacts (S) close for time cycle. Models 5014 and 5015 have the same
switch arrangement except for only four SPDT switches and four auxiliary
contacts. Models 5011 and 5014 are slave units.
|
| |
|
| Specifications |
| Time
Cycle: |
Adjustable
in 2-minute increments from 2 to 120 minutes. |
| Motor: |
Synchronous
type, completely sealed and lubricated |
| Motor
Power: |
4
watts |
Motor
Temperature
Range: |
(ambient):
35°F to 175°F. |
| Base:
|
All steel
construction, 16 gauge channeled steel. zinc plated for corrosion
resistance and durability. |
| Mounting: |
See above |
| Contact
Transfers: |
Maximum
number of contact transfers per 24-hour period for each program
timer is 64 (8 switch unit) or 32 (4 switch unit). |
| Terminals: |
1/4 inch
male quick connect (standard). |
|
This accurate, multi-circuit
timing device can individually operate from one to 24 switches. It
is designed to control a series of operations with a variable time
sequence, such as a refrigeration defrost cycle. Built with positive
snap-action switches to provide positive and immediate switching.
this field-adjustable defrost control combines ease of programming
with accuracy and reliability.
• The 5000 Series provides a high
level of adjustment flexibility. The basic units are with either four
or eight sequentially programmed SPDT, 15 amp., cam-operated switches.
It differs from common multi-circuit controls in that each switch
is independently controlled by the combined action of two separate
time shafts. This arrangement makes it possible to combine extremely
short “on” periods with extremely long “off”
periods, such as a two-minute “on “ period once a day. |
•Switches
can be cycled independently at selected times for independently adjusted
“on” periods. For example, one switch can be adjusted
to operate eight times a day, with a 10-minute “on” period.
Each switch is actuated by an individually adjustable cycle timer
consisting of a cam assembly with a drive gear designed to rotate
one revolution at relatively high speed and stop, giving one cycle
to the switch. Each cycle timer is initiated by an individual program
timer which rotates at the relatively slow speed of one revolution
per 24 hours and includes a molded dial with slots into which trippers
can be inserted. In operation, a tripper in the program timer starts
the cycle timer, which then goes through one cycle and comes to rest.
Placement of the trippers determines when “on” periods
occur. Adjustment of the cycle timer determines the length of the
“on” periods.
• The 5000 Series defrost control
is available as a master unit with a synchronous drive motor and either
four or eight individually controlled switches—or as a slave
unit (without a motor) of either four or eight individually controlled
switches. Up to 24 switches can be operated by combining slave units
with just a single master unit.
• Master units have one industrial-duty
synchronous motor that is designed for long life. |
|
defrost timers
defrost controls
Supplying high quality defrost timers to defrost timer market for over
40 years.
defrost timers are U.L. listed 40 amps.
Our defrost timers product line includes:
Direct Paragon replacement defrost timers (movement only) for Paragon
Timer 8041-00, Paragon Timer 8041-20, Paragon Timer 8043-00, Paragon Timer
8043-20, Paragon Timer 8045-00, Paragon Timer 8045-20, Paragon Timer 8047-00,
Paragon Timer 8047-20, Paragon Timer 8141-00, Paragon Timer 8141-20, Paragon
Timer 8143-00, Paragon Timer 8143-20, Paragon Timer 8145-00, Paragon Timer
8145-20
defrost timer
defrost timers
defrost control
defrost controls
Paragon replacement timers
|